How to Choose a DC-DC Converter for Honda Acty: 144V to 12V

Converting a Honda Acty to electric requires a reliable 144V to 12V DC-DC converter to power 12V systems (lights, ECU, infotainment, etc.). Selecting the right converter ensures stable voltage, safety, and compatibility. Here’s a step-by-step guide focusing on key technical and practical factors:
1. Determine Power Requirements Calculate the total 12V load to size the converter properly:

● 

Essential loads: Headlights (100–150W), taillights (20–30W), ECU (50–80W), wipers (100W), horn (100W) → ~350–430W

● 

Optional loads: Infotainment (50–100W), heated seats (100–200W), cooling fans (50–100W) → +200–350W

● 

Total: 550–780W (add 20% margin for surges) → Choose a 700–1000W converter for safety and longevity.
2. Input & Output Specifications

● 

Input Voltage: Must tolerate 144V nominal with a range (e.g., 120–180V) to handle battery voltage fluctuations (e.g., 120V when low, 168V when fully charged).

● 

Output Voltage: Stable 12V ±5% (11.4–12.6V) to avoid damaging 12V electronics. Ensure it meets automotive standards (e.g., ISO 16750-2) for voltage ripple (≤200mV).

● 

Output Current: For a 700W converter, output current = 700W / 12V ≈ 58A. Confirm the converter supports this continuously.
3. Efficiency & Thermal Management

● 

Efficiency: Opt for ≥92% efficiency (e.g., 92–95%). Higher efficiency reduces heat generation and battery drain. For example, a 95% efficient 700W converter only wastes 35W as heat (vs. 56W for 92% efficiency).

● 

Cooling: Use a liquid-cooled or forced-air cooled converter. The Acty’s compact engine bay limits airflow, so liquid cooling (connected to the motor’s coolant loop) is ideal for high-power converters (≥700W). Ensure the cooling system matches the converter’s thermal design (e.g., coolant flow rate, inlet/outlet ports).
4. Protection Features The converter must protect against common automotive electrical issues:

● 

Overvoltage/Undervoltage: Auto-shutdown if input <120V or >180V (to protect 12V systems).

● 

Overcurrent/Short Circuit: Auto-recovery (e.g., reduces output current during a short, resets when the fault clears).

● 

Overtemperature: Reduces output power or shuts down if internal temperature exceeds safe limits (e.g., >85°C).

● 

Reverse Polarity: Prevents damage if input wires are reversed during installation.
5. Physical & Mounting Considerations

● 

Size & Weight: Choose a compact, lightweight converter (e.g., ≤2–3 kg) to fit the Acty’s tight engine bay. Measure the available space (e.g., near the battery or transmission) to ensure a snug fit.

● 

Mounting: Use anti-vibration mounts (e.g., rubber bushings) to handle road shocks. Ensure the mounting points align with the Acty’s chassis (e.g., M6 or M8 bolts).
6. Compliance & Reliability

● 

Automotive Standards: Ensure the converter meets automotive certifications (e.g., AEC-Q100 for components, ISO 16750-2 for environmental testing). This guarantees reliability in temperature extremes (e.g., -40°C to 85°C) and vibration.

● 

EMI/EMC: Low electromagnetic interference (EMI) to avoid disrupting the Acty’s ECU or radio. Look for converters with built-in EMI filters.
7. Integration with Acty’s Systems

● 

Control Signals: The converter should support “Enable/Disable” signals (e.g., from the ignition switch). This turns the 12V output on only when the EV is running, saving battery power.

● 

Monitoring: Choose a converter with CAN bus or analog output (e.g., 0–5V) to monitor input/output voltage, current, and temperature. This integrates with the Acty’s dashboard or BMS for real-time diagnostics.
8. Installation & Safety

● 

Wiring: Use 12V cables rated for the converter’s output current (e.g., 6 AWG for 60A). Keep 12V wiring short to reduce voltage drop (e.g., ≤1 meter from the converter to the 12V fuse box).

● 

Fusing: Add a 60–70A fuse on the 12V output line (close to the converter) to protect against short circuits.

● 

Grounding: Connect the converter’s ground to the Acty’s chassis ground (near the battery) to avoid ground loops.
9. Example Specification for Honda Acty For a 25KW (45KW peak) PMSM motor system:

● 

Converter: 144V to 12V, 800W (66A output), ≥93% efficiency, liquid-cooled

● 

Input Range: 120–180V

● 

Output: 12V ±3%, ripple ≤150mV

● 

Protections: Overvoltage, overcurrent, overtemperature, short circuit

● 

Size: ≤200×150×50 mm, 2.5 kg

● 

Certifications: AEC-Q100, ISO 16750-2

● 

Cooling: Liquid-cooled (connects to motor’s coolant loop)
10. Testing & Validation

● 

Bench Test: Run the converter at 800W for 1 hour. Monitor output voltage, temperature, and efficiency.

● 

Vehicle Test: Install in the Acty. Test at low (120V) and high (168V) battery voltages. Check 12V system stability (e.g., lights don’t flicker, ECU operates normally).

● 

Long-Term Test: Run the Acty for 200+ km. Monitor the converter’s temperature and output under different loads (e.g., headlights + wipers + infotainment).
A well-chosen 144V-12V DC-DC converter ensures the Acty’s 12V systems run reliably. By focusing on power capacity, efficiency, protection, and integration, you’ll create a safe and stable power solution for the oil-to-electric conversion.
Previous Post

How to Make a Suitable Coupler for Honda Acty in Oil-to-Electric Conversion?

Next Post

Choose a battery meter for HondaActy ?

Leave a Reply